Title: Operation of the RHIC Beam Dump Thyratron CX1575C

Abstract

Applying the knowledge gained with these tests, a procedure to allow running at design voltages was developed and successfully applied to the thyratrons SN #1630 and #1632. The procedure is based on the premise, that the reservoir heater voltage should be set to the highest level compatible with the tube hold-off voltage being maintained, since high gas pressure provides adequate plasma current and prevents ion bombardment and damage of the electrodes. This is recommended in the data sheet for the different purpose of achieving maximum rate of rise of current.

Authors:
 [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)
Publication Date:
Research Org.:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1119252
Report Number(s):
BNL-101910-2013-IR
DOE Contract Number:  
AC02-98CH10886
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS

Citation Formats

Hahn, H., and Dunbar, A. Operation of the RHIC Beam Dump Thyratron CX1575C. United States: N. p., 1999. Web. doi:10.2172/1119252.
Hahn, H., & Dunbar, A. Operation of the RHIC Beam Dump Thyratron CX1575C. United States. doi:10.2172/1119252.
Hahn, H., and Dunbar, A. Tue . "Operation of the RHIC Beam Dump Thyratron CX1575C". United States. doi:10.2172/1119252. https://www.osti.gov/servlets/purl/1119252.
@article{osti_1119252,
title = {Operation of the RHIC Beam Dump Thyratron CX1575C},
author = {Hahn, H. and Dunbar, A.},
abstractNote = {Applying the knowledge gained with these tests, a procedure to allow running at design voltages was developed and successfully applied to the thyratrons SN #1630 and #1632. The procedure is based on the premise, that the reservoir heater voltage should be set to the highest level compatible with the tube hold-off voltage being maintained, since high gas pressure provides adequate plasma current and prevents ion bombardment and damage of the electrodes. This is recommended in the data sheet for the different purpose of achieving maximum rate of rise of current.},