SAMPLE RESULTS FROM THE NEXT GENERATION SOLVENT PROGRAM REAL WASTE EXTRACTION-SCRUB-STRIP TESTING
Abstract
Savannah River National Laboratory (SRNL) performed multiple Extraction-Scrub-Strip (ESS) testing using real waste solutions, and three Next Generation Solvent (NGS) variations, which included radiologically clean pure NGS, a blend of radiologically clean NGS and radiologically clean BOBCalixC6 (NGS-MCU), and a blend of radiologically clean NGS and radiologically contaminated BOBCalixC6 from the MCU Solvent system. The results from the tests indicate that both the NGS and the NGS-MCU blend exhibit adequate extraction, scrub and strip behavior.
- Authors:
- Publication Date:
- Research Org.:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 1084442
- Report Number(s):
- SRNL-STI-2013-00256
TRN: US1300096
- DOE Contract Number:
- DE-AC09-08SR22470
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; MCU, ESS, NGS, Real Waste, ISDP
Citation Formats
Peters, T., and Washington, A. SAMPLE RESULTS FROM THE NEXT GENERATION SOLVENT PROGRAM REAL WASTE EXTRACTION-SCRUB-STRIP TESTING. United States: N. p., 2013.
Web. doi:10.2172/1084442.
Peters, T., & Washington, A. SAMPLE RESULTS FROM THE NEXT GENERATION SOLVENT PROGRAM REAL WASTE EXTRACTION-SCRUB-STRIP TESTING. United States. https://doi.org/10.2172/1084442
Peters, T., and Washington, A. 2013.
"SAMPLE RESULTS FROM THE NEXT GENERATION SOLVENT PROGRAM REAL WASTE EXTRACTION-SCRUB-STRIP TESTING". United States. https://doi.org/10.2172/1084442. https://www.osti.gov/servlets/purl/1084442.
@article{osti_1084442,
title = {SAMPLE RESULTS FROM THE NEXT GENERATION SOLVENT PROGRAM REAL WASTE EXTRACTION-SCRUB-STRIP TESTING},
author = {Peters, T. and Washington, A.},
abstractNote = {Savannah River National Laboratory (SRNL) performed multiple Extraction-Scrub-Strip (ESS) testing using real waste solutions, and three Next Generation Solvent (NGS) variations, which included radiologically clean pure NGS, a blend of radiologically clean NGS and radiologically clean BOBCalixC6 (NGS-MCU), and a blend of radiologically clean NGS and radiologically contaminated BOBCalixC6 from the MCU Solvent system. The results from the tests indicate that both the NGS and the NGS-MCU blend exhibit adequate extraction, scrub and strip behavior.},
doi = {10.2172/1084442},
url = {https://www.osti.gov/biblio/1084442},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jun 03 00:00:00 EDT 2013},
month = {Mon Jun 03 00:00:00 EDT 2013}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.