Microwave proton source development for a high-current linac injector
- Los Alamos National Lab., NM (United States). Accelerator Operations and Technology Div.; and others
Powerful CW proton linear accelerators (100-mA at 0.5--1.0 GeV) are being proposed for spallation neutron-source applications. A 75-keV, 110-mA dc proton injector using a microwave ion source is being tested for these applications. It has achieved 80-keV, 110-mA hydrogen-ion-beam operation. Video and dc beam-current toroid diagnostics are operational, and an EPICS control system is also operational on the 75-keV injector. A technical base development program has also been carried out on a 50-keV injector obtained from Chalk River Laboratories, and it includes low-energy beam transport studies, ion source lifetime tests, and proton-fraction enhancement studies. Technical base results and the present status of the 75-keV injector will be presented.
- Research Organization:
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 106614
- Report Number(s):
- LA-UR-95-3091; CONF-9509125-1; ON: DE96000050; TRN: 95:022044
- Resource Relation:
- Conference: 6. international conference on ion sources, Whistler (Canada), 10-16 Sep 1995; Other Information: PBD: [1995]
- Country of Publication:
- United States
- Language:
- English