Title: Mach-Zehnder Fiber-Optic Links for ICF Diagnostics

Abstract

This article describes the operation and evolution of Mach-Zehnder links for single-point detectors in inertial confinement fusion experimental facilities, based on the Gamma Reaction History (GRH) diagnostic at the National Ignition Facility.

Authors:
Publication Date:
Research Org.:
Nevada Test Site/National Security Technologies, LLC (United States)
Sponsoring Org.:
USDOE NA Office of Defense Programs (NA-10)
OSTI Identifier:
1055488
Report Number(s):
DOE/NV/25946-1576
DOE Contract Number:  
DE-AC52-06NA25946
Resource Type:
Journal Article
Journal Name:
Stockpile Stewardship Quarterly
Additional Journal Information:
Journal Volume: 2; Journal Issue: 3
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; Mach-Zehnder, inertial confinement fusion

Citation Formats

Miller, E. K., Hermann, H. W. Mach-Zehnder Fiber-Optic Links for ICF Diagnostics. United States: N. p., 2012. Web.
Miller, E. K., Hermann, H. W. Mach-Zehnder Fiber-Optic Links for ICF Diagnostics. United States.
Miller, E. K., Hermann, H. W. Thu . "Mach-Zehnder Fiber-Optic Links for ICF Diagnostics". United States.
@article{osti_1055488,
title = {Mach-Zehnder Fiber-Optic Links for ICF Diagnostics},
author = {Miller, E. K., Hermann, H. W.},
abstractNote = {This article describes the operation and evolution of Mach-Zehnder links for single-point detectors in inertial confinement fusion experimental facilities, based on the Gamma Reaction History (GRH) diagnostic at the National Ignition Facility.},
doi = {},
journal = {Stockpile Stewardship Quarterly},
number = 3,
volume = 2,
place = {United States},
year = {2012},
month = {11}
}