NCRF gun status and test plan
Conference
·
OSTI ID:1048802
- Los Alamos National Laboratory
Summary of this presentation are: (1) NCRF injector has achieved >7MV/m average gradients; (2) RGA trace shows little water in cathode cell; (3) NCRF injector has produced electron beams; (4) Dark current can be reduced with solenoid magnetic field; (5) An RF window failed at RF power above 800kW; (6) Beam tests will be performed with both RLWG (each exposed to 500kW of RF power); and (7) Beam tests will use CsK{sub 2}Sb photocathodes fabricated using low-temperature alkali sources.