skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of NDA and DA measurement techniques for excess plutonium powders at the Hanford Site: Statistical design and heterogeneity testing

Conference ·
OSTI ID:104770
; ;  [1];  [2];  [3]; ;  [4];  [5]
  1. Westinghouse Hanford Co., Richland, WA (United States)
  2. Pacific Northwest Lab., Richland, WA (United States)
  3. USDOE Richland Operations Office, WA (United States)
  4. International Atomic Energy Agency, Vienna (Austria)
  5. International Atomic Energy Agency, Toronto, Ontario (Canada)

Quantitative physical measurements are a n component of the International Atomic Energy Agency (IAEA) nuclear material m&guards verification regime. In December 1994, LA.FA safeguards were initiated on an inventory of excess plutonium powder items at the Plutonium Finishing Plant, Vault 3, on the US Department of Energy`s Hanford Site. The material originl from the US nuclear weapons complex. The diversity of the chemical form and the heterogenous physical form of this inventory were anticipated to challenge the precision and accuracy of quantitative destructive analytical techniques. A sampling design was used to estimate the degree of heterogeneity of the plutonium content of a variety of inventory items. Plutonium concentration, the item net weight, and the {sup 240}Pu content were among the variables considered in the design. Samples were obtained from randomly selected location within each item. Each sample was divided into aliquots and analyzed chemically. Operator measurements by calorimetry and IAEA measurements by coincident neutron nondestructive analysis also were performed for the initial physical inventory verification materials and similar items not yet under IAEA safeguards. The heterogeneity testing has confirmed that part of the material is indeed significantly heterogeneous; this means that precautionary measures must be taken to obtain representative samples for destructive analysis. In addition, the sampling variability due to material heterogeneity was found to be comparable with, or greater than, the variability of the operator`s calorimetric measurements.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
104770
Report Number(s):
WHC-SA-2834; CONF-950787-26; ON: DE95015738; TRN: 95:020344
Resource Relation:
Conference: 36. annual meeting of the Institute for Nuclear Materials Management, Palm Desert, CA (United States), 9-12 Jul 1995; Other Information: PBD: Jun 1995
Country of Publication:
United States
Language:
English