Title: MicroCT: Semi-Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI

Abstract

This Standard Operating Procedure (SOP) provides the specific procedural steps for analyzing reconstructed CT images obtained under the IDD Standard Operating Procedures for data acquisition [1] and MicroCT image reconstruction [2], per the IDD Quality Assurance Plan for MicroCT Scanning [3]. Although intended to apply primarily to MicroCT data acquired in the HEAFCAT Facility at LLNL, these procedures may also be applied to data acquired at Tyndall from the YXLON cabinet and at TSL from the HEXCAT system. This SOP also provides the procedural steps for preparing the tables and graphs to be used in the reporting of analytical results. This SOP applies to R and D work - for production applications, use [4].

Authors:
; ; ; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1037842
Report Number(s):
LLNL-TR-503292
TRN: US201208%%210
DOE Contract Number:
W-7405-ENG-48
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; DATA ACQUISITION; EXPLOSIVES; LAWRENCE LIVERMORE NATIONAL LABORATORY; PRODUCTION; QUALITY ASSURANCE

Citation Formats

Seetho, I M, Brown, W D, Kallman, J S, Martz, H E, and White, W T. MicroCT: Semi-Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI. United States: N. p., 2011. Web. doi:10.2172/1037842.
Seetho, I M, Brown, W D, Kallman, J S, Martz, H E, & White, W T. MicroCT: Semi-Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI. United States. doi:10.2172/1037842.
Seetho, I M, Brown, W D, Kallman, J S, Martz, H E, and White, W T. Thu . "MicroCT: Semi-Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI". United States. doi:10.2172/1037842. https://www.osti.gov/servlets/purl/1037842.
@article{osti_1037842,
title = {MicroCT: Semi-Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI},
author = {Seetho, I M and Brown, W D and Kallman, J S and Martz, H E and White, W T},
abstractNote = {This Standard Operating Procedure (SOP) provides the specific procedural steps for analyzing reconstructed CT images obtained under the IDD Standard Operating Procedures for data acquisition [1] and MicroCT image reconstruction [2], per the IDD Quality Assurance Plan for MicroCT Scanning [3]. Although intended to apply primarily to MicroCT data acquired in the HEAFCAT Facility at LLNL, these procedures may also be applied to data acquired at Tyndall from the YXLON cabinet and at TSL from the HEXCAT system. This SOP also provides the procedural steps for preparing the tables and graphs to be used in the reporting of analytical results. This SOP applies to R and D work - for production applications, use [4].},
doi = {10.2172/1037842},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Sep 22 00:00:00 EDT 2011},
month = {Thu Sep 22 00:00:00 EDT 2011}
}

Technical Report:

Save / Share: