skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: INTEGRATED DM 1200 MELTER TESTING OF HLW C-106/AY-102 COMPOSITION USING BUBBLERS VSL-03R3800-1 REV 0 9/15/03

Abstract

This report documents melter and off-gas performance results obtained on the DM1200 HLW Pilot Melter during processing of simulated HLW C-106/AY-102 feed. The principal objectives of the DM1200 melter testing were to determine the achievable glass production rates for simulated HLW C-106/AY-102 feed; determine the effect of bubbling rate on production rate; characterize melter off-gas emissions; characterize the performance of the prototypical off-gas system components as well as their integrated performance; characterize the feed, glass product, and off-gas effluents; and to perform pre- and post test inspections of system components.

Authors:
; ; ; ; ; ;
Publication Date:
Research Org.:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Environmental Management (EM)
OSTI Identifier:
1034652
Report Number(s):
ORP-51439 Rev 0
VSL-03R3800-1, Rev. 0, 9/15/2003; TRN: US1200888
DOE Contract Number:  
DE-AC27-08RV14800
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; GLASS; OFF-GAS SYSTEMS; PERFORMANCE; PROCESSING; PRODUCTION; TESTING

Citation Formats

KRUGER AA, MATLACK KS, GONG W, BARDAKCI T, D'ANGELO NA, KOT WK, and PEGG IL. INTEGRATED DM 1200 MELTER TESTING OF HLW C-106/AY-102 COMPOSITION USING BUBBLERS VSL-03R3800-1 REV 0 9/15/03. United States: N. p., 2011. Web. doi:10.2172/1034652.
KRUGER AA, MATLACK KS, GONG W, BARDAKCI T, D'ANGELO NA, KOT WK, & PEGG IL. INTEGRATED DM 1200 MELTER TESTING OF HLW C-106/AY-102 COMPOSITION USING BUBBLERS VSL-03R3800-1 REV 0 9/15/03. United States. doi:10.2172/1034652.
KRUGER AA, MATLACK KS, GONG W, BARDAKCI T, D'ANGELO NA, KOT WK, and PEGG IL. Thu . "INTEGRATED DM 1200 MELTER TESTING OF HLW C-106/AY-102 COMPOSITION USING BUBBLERS VSL-03R3800-1 REV 0 9/15/03". United States. doi:10.2172/1034652. https://www.osti.gov/servlets/purl/1034652.
@article{osti_1034652,
title = {INTEGRATED DM 1200 MELTER TESTING OF HLW C-106/AY-102 COMPOSITION USING BUBBLERS VSL-03R3800-1 REV 0 9/15/03},
author = {KRUGER AA and MATLACK KS and GONG W and BARDAKCI T and D'ANGELO NA and KOT WK and PEGG IL},
abstractNote = {This report documents melter and off-gas performance results obtained on the DM1200 HLW Pilot Melter during processing of simulated HLW C-106/AY-102 feed. The principal objectives of the DM1200 melter testing were to determine the achievable glass production rates for simulated HLW C-106/AY-102 feed; determine the effect of bubbling rate on production rate; characterize melter off-gas emissions; characterize the performance of the prototypical off-gas system components as well as their integrated performance; characterize the feed, glass product, and off-gas effluents; and to perform pre- and post test inspections of system components.},
doi = {10.2172/1034652},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Dec 29 00:00:00 EST 2011},
month = {Thu Dec 29 00:00:00 EST 2011}
}

Technical Report:

Save / Share: