Title: Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique

Abstract

A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.

Authors:
Publication Date:
Research Org.:
Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1032486
Report Number(s):
JLAB-PHY-09-1066; DOE/OR/23177-1034; arXiv:0910.3011
Journal ID: ISSN 0168-9002; NIMAER; TRN: US1200517
DOE Contract Number:  
AC05-06OR23177
Resource Type:
Journal Article
Journal Name:
Nuclear Instruments and Methods in Physics Research, Section A
Additional Journal Information:
Journal Volume: 652; Journal Issue: 1; Journal ID: ISSN 0168-9002
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ACCURACY; ATOMIC CLOCKS; CALIBRATION; FREQUENCY MEASUREMENT; STABILITY; MEASURING INSTRUMENTS; MHZ RANGE; OPTICAL SYSTEMS; PHOTONS; PHOTOTUBES; RESOLUTION; RF SYSTEMS; TIMING PROPERTIES

Citation Formats

Margaryan, Amur. Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique. United States: N. p., 2011. Web. doi:10.1016/j.nima.2010.08.122.
Margaryan, Amur. Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique. United States. doi:10.1016/j.nima.2010.08.122.
Margaryan, Amur. Sat . "Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique". United States. doi:10.1016/j.nima.2010.08.122. https://www.osti.gov/servlets/purl/1032486.
@article{osti_1032486,
title = {Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique},
author = {Margaryan, Amur},
abstractNote = {A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.},
doi = {10.1016/j.nima.2010.08.122},
journal = {Nuclear Instruments and Methods in Physics Research, Section A},
issn = {0168-9002},
number = 1,
volume = 652,
place = {United States},
year = {2011},
month = {10}
}