Title: Exhaust Fan Temperature Switch

Abstract

The 13000 cfm 'emergency' vent fan must be protected from over cooling which would result in a mechanical failure. Over cooling could result from a catastrophic cryogen release from the cryostat(s) or Argon Storage Dewar. In order to protect the fan, a VPT has been calibrated for -31 C to open a switch which sends a signal to allow warm gas to enter the sump by means of a motor controlled louver installed at 'sidewalk level' in the ductwork between the assembly hall and the Argon Dewar Enclosure. The bulb of the VPT is enclosed in a thermal well and will be placed in the gas stream directly above the fan. The switching unit will be mounted nearby on the wall in order to isolate it from vibrational effects. Should the fan be activated due to a cryogen release, it should not experience any problems when operating above -40 C. The switch was set and checked in a saturated calcium chloride solution cooled to -31 C by running cold gaseous Nitrogen through a copper tube coiled in a dewar. Switching temperature was measured by a thermocouple tied to the VPT bulb. The thermocouple was checked in LN2, in an icemore » water bath, and against an ordinary thermometer (which was assumed to be accurate to plus or minus 0.3 C) at room temperature. The results are shown below in 'Table 1' By interpolation of the data, thermocouple error at -31.0 C was found to be 0.43 C on the warm side. Since this error was small, it was ignored. 'Table 2' shows the results of the tests. Ten readings were taken with the switch wired in the 'normally open' mode. This results in a signal at room temperature. The worst deviation was 2.5 C. Three readings were then taken from the 'normally closed' wiring arrangement (the way it will be wired for installation). The greatest deviation was 1.2 C. The next day, the switch was checked five times wired in the 'normally open' configuration. The greatest error was 1.1 C. A graph has been prepared showing the switching and resetting temperatures. The errors these tests bore out do not threaten the exhaust fan and are therefore acceptable.« less

Authors:
;
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1031143
Report Number(s):
FERMILAB-D0-EN-210
TRN: US201201%%639
DOE Contract Number:  
AC02-07CH11359
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS; ARGON; BLOWERS; CALCIUM CHLORIDES; CONFIGURATION; COPPER; CRYOGENIC FLUIDS; DEWARS; INTERPOLATION; MOTORS; NITROGEN; STORAGE; THERMOCOUPLES; THERMOMETERS; WATER; Experiment-HEP

Citation Formats

Ball, G.S., and /Fermilab. Exhaust Fan Temperature Switch. United States: N. p., 1989. Web. doi:10.2172/1031143.
Ball, G.S., & /Fermilab. Exhaust Fan Temperature Switch. United States. doi:10.2172/1031143.
Ball, G.S., and /Fermilab. Thu . "Exhaust Fan Temperature Switch". United States. doi:10.2172/1031143. https://www.osti.gov/servlets/purl/1031143.
@article{osti_1031143,
title = {Exhaust Fan Temperature Switch},
author = {Ball, G.S. and /Fermilab},
abstractNote = {The 13000 cfm 'emergency' vent fan must be protected from over cooling which would result in a mechanical failure. Over cooling could result from a catastrophic cryogen release from the cryostat(s) or Argon Storage Dewar. In order to protect the fan, a VPT has been calibrated for -31 C to open a switch which sends a signal to allow warm gas to enter the sump by means of a motor controlled louver installed at 'sidewalk level' in the ductwork between the assembly hall and the Argon Dewar Enclosure. The bulb of the VPT is enclosed in a thermal well and will be placed in the gas stream directly above the fan. The switching unit will be mounted nearby on the wall in order to isolate it from vibrational effects. Should the fan be activated due to a cryogen release, it should not experience any problems when operating above -40 C. The switch was set and checked in a saturated calcium chloride solution cooled to -31 C by running cold gaseous Nitrogen through a copper tube coiled in a dewar. Switching temperature was measured by a thermocouple tied to the VPT bulb. The thermocouple was checked in LN2, in an ice water bath, and against an ordinary thermometer (which was assumed to be accurate to plus or minus 0.3 C) at room temperature. The results are shown below in 'Table 1' By interpolation of the data, thermocouple error at -31.0 C was found to be 0.43 C on the warm side. Since this error was small, it was ignored. 'Table 2' shows the results of the tests. Ten readings were taken with the switch wired in the 'normally open' mode. This results in a signal at room temperature. The worst deviation was 2.5 C. Three readings were then taken from the 'normally closed' wiring arrangement (the way it will be wired for installation). The greatest deviation was 1.2 C. The next day, the switch was checked five times wired in the 'normally open' configuration. The greatest error was 1.1 C. A graph has been prepared showing the switching and resetting temperatures. The errors these tests bore out do not threaten the exhaust fan and are therefore acceptable.},
doi = {10.2172/1031143},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu May 11 00:00:00 EDT 1989},
month = {Thu May 11 00:00:00 EDT 1989}
}

Technical Report:

Save / Share: