We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields (- 1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

Authors:
; ; ; ; ; ; ;  [1]
  1. X-Ray Science Division
Publication Date:
Research Org.:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1027198
Report Number(s):
ANL/XSD/JA-65127
Journal ID: ISSN 0034-6748; RSINAK; TRN: US201121%%353
DOE Contract Number:  
DE-AC02-06CH11357
Resource Type:
Journal Article
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 80; Journal Issue: 11; Journal ID: ISSN 0034-6748
Country of Publication:
United States
Language:
ENGLISH
Subject:
47 OTHER INSTRUMENTATION; CAPACITORS; CRYOSTATS; HELIUM; MAGNET COILS; MAGNETIC FIELDS; MAGNETS; SCATTERING; STORAGE; X-RAY DIFFRACTION

Citation Formats

Islam, Z, Ruff, J P.C., Nojiri, H, Matsuda, Y H, Ross, K A, Gaulin, B D, Qu, Z, Lang, J C, PSC-USR), McMaster Univ.), Tohoku Univ.), and Tulane Univ.). A portable high-field pulsed magnet system for x-ray scattering studies.. United States: N. p., 2009. Web. doi:10.1063/1.3251273.
Islam, Z, Ruff, J P.C., Nojiri, H, Matsuda, Y H, Ross, K A, Gaulin, B D, Qu, Z, Lang, J C, PSC-USR), McMaster Univ.), Tohoku Univ.), & Tulane Univ.). A portable high-field pulsed magnet system for x-ray scattering studies.. United States. https://doi.org/10.1063/1.3251273
Islam, Z, Ruff, J P.C., Nojiri, H, Matsuda, Y H, Ross, K A, Gaulin, B D, Qu, Z, Lang, J C, PSC-USR), McMaster Univ.), Tohoku Univ.), and Tulane Univ.). 2009. "A portable high-field pulsed magnet system for x-ray scattering studies.". United States. https://doi.org/10.1063/1.3251273.
@article{osti_1027198,
title = {A portable high-field pulsed magnet system for x-ray scattering studies.},
author = {Islam, Z and Ruff, J P.C. and Nojiri, H and Matsuda, Y H and Ross, K A and Gaulin, B D and Qu, Z and Lang, J C and PSC-USR) and McMaster Univ.) and Tohoku Univ.) and Tulane Univ.)},
abstractNote = {We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields (- 1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.},
doi = {10.1063/1.3251273},
url = {https://www.osti.gov/biblio/1027198}, journal = {Review of Scientific Instruments},
issn = {0034-6748},
number = 11,
volume = 80,
place = {United States},
year = {Thu Jan 01 00:00:00 EST 2009},
month = {Thu Jan 01 00:00:00 EST 2009}
}