Title: RESULTS FOR THE FIRST QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

Technical Report ·
DOI:https://doi.org/10.2172/1023275· OSTI ID:1023275

This report details the chemical and radionuclide contaminant results for the characterization of the 2011 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section; (2) The reported detection limit for {sup 59}Ni is above both the requested limits from Reference 2 and the established limits in Reference 3; (3) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2; however, it is below the established limits in Reference 3. This is a change from previously reported results; (4) The reported concentration of {sup 242m}Am is above the target in Listed in Attachment 8.4 of the Saltstone WAC. This is a change from the previously reported results; (5) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3; (6) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC; (7) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC; and (8) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC09-08SR22470
OSTI ID:
1023275
Report Number(s):
SRNL-STI-2011-00303; TRN: US1104411
Country of Publication:
United States
Language:
English