A pulsed septum magnet for the APS
A pulsed septum magnet has been designed and constructed for beam injection and extraction in the Advanced Photon Source at Argonne National Laboratory. The magnets will be similar for the Positron Accumulator Ring (PAR), the Injector Synchrotron, and the Storage Ring. The septum itself is 2 mm thick and consists of 1-mm-thick copper and S1010 steel explosion-bonded together. The PAR magnet is driven by a 1500-Hz, 12-kA half sine wave current pulse. The core is made of 0.36-mm-thick laminations of silicon steel. The nearly uniform interior field is 0.75 T and the exterior field is 0.0004 T at the undisturbed beam position and 0.0014 T at the bumped beam position. Testing of the magnet awaits the completion of the power supply.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 10175282
- Report Number(s):
- ANL/ASD/CP-78295; CONF-930511-277; ON: DE93017425; TRN: 93:017947
- Resource Relation:
- Conference: PAC `93: international particle accelerator conference,Washington, DC (United States),17-20 May 1993; Other Information: PBD: [1993]
- Country of Publication:
- United States
- Language:
- English
Similar Records
Circuit description of the power systems for pulsed septum magnets at APS
The APS direct-drive pulsed septum magnets