Title: Advanced high-explosive flux compression generator development: The CN-III series

Technical Report ·
OSTI ID:10171530

A very successful series of three flux compression generator (FCG) experiments and one hydro-only test, designed to quantify the performance capabilities and limitations of high-current, high-field, high-power coaxial FCGs, is reported. In the last test, the CN-III FCG produced a peak current of >150 MA with a final doubling time of <10{mu}s into a 2-nH inductive load. Experimental results are in excellent agreement with extensive preshot and postshot one-dimensional (1D) and two-dimensional (2D) magnetohydrodynamic (MHD) calculations.

Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
10171530
Report Number(s):
LA-12348; ON: DE92019962
Resource Relation:
Other Information: PBD: Aug 1992
Country of Publication:
United States
Language:
English