Title: Hazard classification assessment for the High Voltage Initiator

Abstract

An investigation was conducted to determine whether the High Voltage Initiator (Sandia p number 395710; Navy NAVSEA No. 6237177) could be assigned a Department of Transportation (DOT) hazard classification of ``IGNITERS, 1.4G, UN0325`` under Code of Federal Regulations, 49 CFR 173.101, when packaged per Mound drawing NXB911442. A hazard classification test was performed, and the test data led to a recommended hazard classification of ``IGNITERS, 1.4G, UN0325,`` based on guidance outlined in DOE Order 1540.2 and 49 CFR 173.56.

Authors:
Publication Date:
Research Org.:
EG and G Mound Applied Technologies, Miamisburg, OH (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10157699
Report Number(s):
MLM-3789
ON: DE94013351
DOE Contract Number:
AC04-88DP43495
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 19 Apr 1994
Country of Publication:
United States
Language:
English
Subject:
45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEFENSE; DETONATORS; CLASSIFICATION; SAFETY; TRANSPORT; PACKAGING; SHOCK ABSORBERS; TESTING; 450100; CHEMICAL EXPLOSIONS AND EXPLOSIVES

Citation Formats

Cogan, J.D. Hazard classification assessment for the High Voltage Initiator. United States: N. p., 1994. Web. doi:10.2172/10157699.
Cogan, J.D. Hazard classification assessment for the High Voltage Initiator. United States. doi:10.2172/10157699.
Cogan, J.D. Tue . "Hazard classification assessment for the High Voltage Initiator". United States. doi:10.2172/10157699. https://www.osti.gov/servlets/purl/10157699.
@article{osti_10157699,
title = {Hazard classification assessment for the High Voltage Initiator},
author = {Cogan, J.D.},
abstractNote = {An investigation was conducted to determine whether the High Voltage Initiator (Sandia p number 395710; Navy NAVSEA No. 6237177) could be assigned a Department of Transportation (DOT) hazard classification of ``IGNITERS, 1.4G, UN0325`` under Code of Federal Regulations, 49 CFR 173.101, when packaged per Mound drawing NXB911442. A hazard classification test was performed, and the test data led to a recommended hazard classification of ``IGNITERS, 1.4G, UN0325,`` based on guidance outlined in DOE Order 1540.2 and 49 CFR 173.56.},
doi = {10.2172/10157699},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Apr 19 00:00:00 EDT 1994},
month = {Tue Apr 19 00:00:00 EDT 1994}
}

Technical Report:

Save / Share:
  • An investigation was made to determine whether the MC3196 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosives per 49 CFR 173.113. This study covers the Propagation Test and the External Heat Test as approved by DOE Albuquerque Operations Office. Test data led to the recommeded hazard classification of detonating fuze, Class C explosives.
  • An investigation was made to determine whether the MC3423 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per Federal Register 49 CFR 173.113, when packaged as specified. This study covers two propagation tests which evaluated the effects of two orientations of the MC3423 in its shipping tray. The method of testing was approved by DOE, Albuquerque Operations Office. Test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive for both orientations of the detonator.
  • An investigation was made to determine whether the MC 3608 Detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per 49 CFR 173.113. This study covers the propagation test as approved by DOE-Albuquerque Operations Office. Analysis of the test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive.
  • This report addresses the cost saving initiative related to generic frequencies for hazards analyses.
  • In September 1981 the National Institute for Occupational Safety and Health (NIOSH) was requested to evaluate exposures to polychlorinated biphenyls (PCBs) and to chlorinated benzenes and ethanes for electricians at High Voltage Maintenance (HVM) Corp., Mentor, Ohio. The HVM Corp. services electrical power transformers and capacitors on a contract basis with the work performed both in the field and at the Mentor facilities. On the basis of the data collected, NIOSH concludes that workers were exposed to potentially toxic concentrations of airborne 1,1,1-trichloroethane and PCBs. Significant PCB contamination of work surfaces demonstrate a potential for continued exposure to PCBs viamore » skin contact and ingestion. PCB blood levels also indicate excessive absorption of PCBs. Recommendations for decontamination of the buildings and exposure controls are offered in Section VIII of this report.« less