Operational experience and maintenance programs of Transamerica Delaval, Inc., diesel generators
Concerns regarding the reliability of large-bore, medium-speed diesel generators manufactured by Transamerica Delaval, Inc. (TDI) for application at domestic nuclear plants were first prompted by a crankshaft failure at Shoreham Nuclear Power Station in August 1983. A number of diesel generator components were identified which had potential deficiencies from a manufacturing and operational standpoint. In response to these problems, 11 (now 8) U.S. nuclear utility owners formed a TDI Diesel Generator Owners Group (Owners Group) to address operational and regulatory issues relative to diesel generator sets used for standby emergency power. The Owners` Group performed extensive design reviews of all key engine components and developed recommendations to be implemented by the individual owners concerning needed component replacements and modifications, component inspections to validate the {open_quotes}as-manufactured{close_quotes} and {open_quotes}as-assembled{close_quotes} quality of key engine components, engine testing, and an enhanced maintenance and surveillance program.
- Research Organization:
- US Nuclear Regulatory Commission (NRC), Washington, DC (United States). Div. of Engineering
- Sponsoring Organization:
- Nuclear Regulatory Commission, Washington, DC (United States)
- OSTI ID:
- 10149796
- Report Number(s):
- NUREG-1416; ON: TI94011611; TRN: 94:005477
- Resource Relation:
- Other Information: PBD: May 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Role of testing in requalifying Transamerica Delaval, Inc. , engines for nuclear service
Plant-specific evaluations of Transamerica Delaval diesel engines for nuclear service