Title: Fire hazards analysis for W-413, West Area Tank Farm Storage and Staging Facility

Abstract

In accordance with DOE Order 5480.7A, a Fire Hazards Analysis must be performed for all new facilities. The purpose of the analysis is to comprehensively assess the risk from fire within individual fire areas in relation to proposed fire protection so as to ascertain whether the fire protection objectives of the Order are met. The Order acknowledges a graded approach commensurate with the hazards involved. Tank Farms Operations must sore/stage material and equipment such as pipes, fittings, conduit, instrumentation and others related items until work packages are ready to work. Consumable materials, such as nut, bolts and welding rod, are also requires to be stored for routine and emergency work. Connex boxes and open storage is currently used for much of the storage because of the limited space at and 272WA. Safety issues based on poor housekeeping and material deteriorating due to weather damage has resulted from this inadequate storage space. It has been determined that a storage building in close proximity to the Tank Farm work force would be cost effective. This facility is classified as a safety class 4 building.

Authors:
;
Publication Date:
Research Org.:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10110548
Report Number(s):
WHC-SD-W413-FHA-001
ON: DE95005073; BR: 35AF11201/35AF11202
DOE Contract Number:  
AC06-87RL10930
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 14 Dec 1994
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; HANFORD RESERVATION; FIRE HAZARDS; FIRES; TANKS; SAFETY; RADIOACTIVE WASTE STORAGE; 052002; WASTE DISPOSAL AND STORAGE

Citation Formats

Huckfeldt, R.A., and Lott, D.T. Fire hazards analysis for W-413, West Area Tank Farm Storage and Staging Facility. United States: N. p., 1994. Web. doi:10.2172/10110548.
Huckfeldt, R.A., & Lott, D.T. Fire hazards analysis for W-413, West Area Tank Farm Storage and Staging Facility. United States. doi:10.2172/10110548.
Huckfeldt, R.A., and Lott, D.T. Wed . "Fire hazards analysis for W-413, West Area Tank Farm Storage and Staging Facility". United States. doi:10.2172/10110548. https://www.osti.gov/servlets/purl/10110548.
@article{osti_10110548,
title = {Fire hazards analysis for W-413, West Area Tank Farm Storage and Staging Facility},
author = {Huckfeldt, R.A. and Lott, D.T.},
abstractNote = {In accordance with DOE Order 5480.7A, a Fire Hazards Analysis must be performed for all new facilities. The purpose of the analysis is to comprehensively assess the risk from fire within individual fire areas in relation to proposed fire protection so as to ascertain whether the fire protection objectives of the Order are met. The Order acknowledges a graded approach commensurate with the hazards involved. Tank Farms Operations must sore/stage material and equipment such as pipes, fittings, conduit, instrumentation and others related items until work packages are ready to work. Consumable materials, such as nut, bolts and welding rod, are also requires to be stored for routine and emergency work. Connex boxes and open storage is currently used for much of the storage because of the limited space at and 272WA. Safety issues based on poor housekeeping and material deteriorating due to weather damage has resulted from this inadequate storage space. It has been determined that a storage building in close proximity to the Tank Farm work force would be cost effective. This facility is classified as a safety class 4 building.},
doi = {10.2172/10110548},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Dec 14 00:00:00 EST 1994},
month = {Wed Dec 14 00:00:00 EST 1994}
}