The effect of turbulence on the stability of liquid jets and the resulting droplet size distributions. Third quarterly technical report, July 1, 1993--September 30, 1993
Abstract
Laminar and turbulent columns of liquids issuing from capillary tubes were studied in order to determine the effects of turbulence on the stability of liquid jets and to establish the influence of liquid turbulence on droplet size distributions after breakup. Two capillary tubes were chosen with diameters D{sub 1}=3.0mm and D{sub 2}=1.2mm; jet Reynolds numbers were 1000--30000, and 400--7200. For water injection into stagnant air, stability curve is bounded by a laminar portion, where a jet radius and {delta}{sub o} initial disturbance amplitude, and a fully developed turbulent portion characterized by high initial disturbance amplitude (ln(a/{delta}{sub o,T}) {approximately} 4.85). In the transition region, ln(a/{delta}{sub o}) is not single valued; it decreases with increasing Reynolds number. In absence of aerodynamic effects, turbulent jets are as stable as laminar jets. For this breakup mode turbulence propagates initial disturbances with amplitudes orders of magnitude larger than laminar jets ({delta}{sub o,T}=28{times}10{sup 6} {delta}{sub o,L}). Growth rates of initial disturbances are same for both laminar and turbulent columns with theoretical Weber values. Droplet size distribution is bi-modal; the number ratio of large (> D/2), to small (< D/2) droplets is 3 and independent of Reynolds number. For laminar flow optimum wavelength ({lambda}{sub opt}) corresponding tomore »
- Authors:
- Publication Date:
- Research Org.:
- Carnegie-Mellon Univ., Pittsburgh, PA (United States). Dept. of Mechanical Engineering
- Sponsoring Org.:
- USDOE, Washington, DC (United States)
- OSTI Identifier:
- 10109151
- Report Number(s):
- DOE/PC/92152-T4
ON: DE94004522; BR: AA1505000
- DOE Contract Number:
- FG22-92PC92152
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: [1993]
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 42 ENGINEERING; LIQUID FLOW; STABILITY; JETS; TURBULENCE; DROPLETS; SIZE; PROGRESS REPORT; WATER; INJECTION; AIR; DISTURBANCES; TUBES; CAPILLARIES; 420400; HEAT TRANSFER AND FLUID FLOW
Citation Formats
Mansour, A., and Chigier, N. The effect of turbulence on the stability of liquid jets and the resulting droplet size distributions. Third quarterly technical report, July 1, 1993--September 30, 1993. United States: N. p., 1993.
Web. doi:10.2172/10109151.
Mansour, A., & Chigier, N. The effect of turbulence on the stability of liquid jets and the resulting droplet size distributions. Third quarterly technical report, July 1, 1993--September 30, 1993. United States. doi:10.2172/10109151.
Mansour, A., and Chigier, N. Wed .
"The effect of turbulence on the stability of liquid jets and the resulting droplet size distributions. Third quarterly technical report, July 1, 1993--September 30, 1993". United States.
doi:10.2172/10109151. https://www.osti.gov/servlets/purl/10109151.
@article{osti_10109151,
title = {The effect of turbulence on the stability of liquid jets and the resulting droplet size distributions. Third quarterly technical report, July 1, 1993--September 30, 1993},
author = {Mansour, A. and Chigier, N.},
abstractNote = {Laminar and turbulent columns of liquids issuing from capillary tubes were studied in order to determine the effects of turbulence on the stability of liquid jets and to establish the influence of liquid turbulence on droplet size distributions after breakup. Two capillary tubes were chosen with diameters D{sub 1}=3.0mm and D{sub 2}=1.2mm; jet Reynolds numbers were 1000--30000, and 400--7200. For water injection into stagnant air, stability curve is bounded by a laminar portion, where a jet radius and {delta}{sub o} initial disturbance amplitude, and a fully developed turbulent portion characterized by high initial disturbance amplitude (ln(a/{delta}{sub o,T}) {approximately} 4.85). In the transition region, ln(a/{delta}{sub o}) is not single valued; it decreases with increasing Reynolds number. In absence of aerodynamic effects, turbulent jets are as stable as laminar jets. For this breakup mode turbulence propagates initial disturbances with amplitudes orders of magnitude larger than laminar jets ({delta}{sub o,T}=28{times}10{sup 6} {delta}{sub o,L}). Growth rates of initial disturbances are same for both laminar and turbulent columns with theoretical Weber values. Droplet size distribution is bi-modal; the number ratio of large (> D/2), to small (< D/2) droplets is 3 and independent of Reynolds number. For laminar flow optimum wavelength ({lambda}{sub opt}) corresponding to fastest growing disturbance is equal to 4.45D, exactly the theoretical Weber value. For turbulent flow conditions, the turbulent column segments. Typically, segments with lengths of one to several wavelengths, detach from the liquid jet. The long ligaments contract under the action of surface tension, resulting in droplet sizes larger than predicted by Rayleigh and Weber. For turbulent flow conditions, {lambda}{sub opt} = 9.2D, about 2 times the optimum Weber wavelength.},
doi = {10.2172/10109151},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Dec 01 00:00:00 EST 1993},
month = {Wed Dec 01 00:00:00 EST 1993}
}
-
In this progress report the authors report on progress in making experimental measurements to describe the rheological properties of non-Newtonian fluids. Non-Newtonian liquids exhibit a non linear relationship between the shear stress and the shear rate. A typical time-dependent rheological phenomenon is thixotropy. Thixotropic fluids show a limited decrease in the shear viscosity of the fluid with time under a suddenly applied constant stress. Thixotropic fluids also show a hysteresis loop and a decaying stress on the shear stress-shear rate plot. Here the authors are using a power law model to describe the behavior of such non-Newtonian liquids.
-
Dow syngas environmental monitoring plan quarterly report for the third quarter, July 1, 1993 through September 30, 1993
The Energy Security Act of 1980 established a program to provide financial assistance to private industry in the construction and operation of commercial-sacle synthetic fuels plants. The Dow Syngas Project design has a high-temperature entrained-flow slagging type gasifier, which began operating in 1987. Dow agreed to comply with existing environmental regulations and to develop an Environmental Monitoring Plan (EMP) incorporating supplemental monitoring in areas of potential environmental and health concern, relative to synthetic fuels facilities. The phases of monitoring in the EMP tests parameters of interest in air, water and solid waste to establish a data base of information thatmore » -
Refining of fossil resin flotation concentrate from Western coal. Third quarterly final report, July 1, 1993--September 30, 1993
Summary of Batch Extraction Experiments: (1) Resin extraction rate is not significantly affected by agitation intensity and low agitation should be suitable for the continuous extraction process; (2) The effect of resin particle size on the extraction rate and yield is obvious. Because of the fine size of the composite resin concentrate (80% minus 200 mesh), the extraction reaction occurs in reasonable times and process design conditions can be established accordingly; (3) The effect of temperature on the rate and yield of the extraction process is found to be very significant. Higher temperatures (about 60{degree}C) should be considered for themore » -
Magnetic relaxation: Coal swelling, extraction, pore size. Quarterly technical progress report, July 1, 1993--September 30, 1993
An electron spin and proton magnetic relaxation study is presented on the effects of the solvent extraction of coal on the macromolecular network of the coal and on the mobile molecular species that are initially within the coal. The eight Argonne Premium coals were extracted at room temperature with a 1:1 (v/v) N-methylpyrrolidinone (NMP)-CS{sub 2} solvent mixture under an inert atmosphere. As much solvent as possible was removed from extract and residue by treatment under vacuum oven conditions ({approximately}10{sup {minus}2} torr at 145--150{degrees}C) until constant weight was achieved. The extraction, without further washing with other solvents, results in substantial uptakemore » -
Accelerated screening methods for determining chemical and thermal stability of refrigerant-lubricant mixtures: Part 2, Experimental comparison and verification of methods. Quarterly technical progress report, 1 July 1993--30 September 1993
Research reported continued to concentrate on in situ conductivity measurements for development of an accelerated screening method for determining the chemical and thermal stabilities of refrigerant/lubricant mixtures. Tungsten rods were sealed into the round bottoms of the sealed tubes to provide electrical connections for in situ conductivity measurements. The in situ conductivity measurements were used to monitor the degradation of HFC-134a/ester oil mixtures heated at 175 C (347 F) for two days. Preliminary results indicate that the in situ conductivity measurements correlate with H-1 34a/oil degradation as determined by color measurements. A short study to evaluate the potential of inmore »