Title: Seismic qualification of a switch box

Abstract

This supporting document details the results of a seismic analysis on a switch box assembly. The switch box is mounted to a Unistrut frame and is attached to the concrete floor in the 225B Building with Hilti Kwik bolts. The assembly was found to meet safety class 3 requirement. Although all components analyzed were found to be structurally adequate, some changes are recommended. To comply with SDC 4.2 specification, the Hilti Kwik bolts should be: placed at least 8 1/4 inches from the edge of the concrete floor; should have a minimum spacing of 8 inches from any Kwik bolt; and should be embedded 5 1/2 inches into the concrete. The minimum embedment distance is 2 3/4 inches. Furthermore, when the bolts are installed, rebar within the concrete should not be cut or damaged. Finally, the length of the Hilti Kwik bolt should be sized such that the distance from the top of the bolt to the top of the nut is not less than 2 thread pitches, and not more that 3/4 inch.

Authors:
Publication Date:
Research Org.:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10105536
Report Number(s):
WHC-SD-WM-ER-393
ON: DE95004365; BR: 35AF11201/35AF11202; TRN: AHC29503%%47
DOE Contract Number:
AC06-87RL10930
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 23 Nov 1994
Country of Publication:
United States
Language:
English
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; 12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; HANFORD RESERVATION; RADIOACTIVE WASTE FACILITIES; SWITCHING CIRCUITS; SAFETY ANALYSIS; SEISMIC EFFECTS; SEISMIC ISOLATION; RECOMMENDATIONS; MODIFICATIONS; 054000; 052001; HEALTH AND SAFETY; WASTE PROCESSING

Citation Formats

Miller, S.M. Seismic qualification of a switch box. United States: N. p., 1994. Web. doi:10.2172/10105536.
Miller, S.M. Seismic qualification of a switch box. United States. doi:10.2172/10105536.
Miller, S.M. Wed . "Seismic qualification of a switch box". United States. doi:10.2172/10105536. https://www.osti.gov/servlets/purl/10105536.
@article{osti_10105536,
title = {Seismic qualification of a switch box},
author = {Miller, S.M.},
abstractNote = {This supporting document details the results of a seismic analysis on a switch box assembly. The switch box is mounted to a Unistrut frame and is attached to the concrete floor in the 225B Building with Hilti Kwik bolts. The assembly was found to meet safety class 3 requirement. Although all components analyzed were found to be structurally adequate, some changes are recommended. To comply with SDC 4.2 specification, the Hilti Kwik bolts should be: placed at least 8 1/4 inches from the edge of the concrete floor; should have a minimum spacing of 8 inches from any Kwik bolt; and should be embedded 5 1/2 inches into the concrete. The minimum embedment distance is 2 3/4 inches. Furthermore, when the bolts are installed, rebar within the concrete should not be cut or damaged. Finally, the length of the Hilti Kwik bolt should be sized such that the distance from the top of the bolt to the top of the nut is not less than 2 thread pitches, and not more that 3/4 inch.},
doi = {10.2172/10105536},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Nov 23 00:00:00 EST 1994},
month = {Wed Nov 23 00:00:00 EST 1994}
}

Technical Report:

Save / Share: