Title: EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR

Abstract

Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.

Authors:
 [1];  [1];  [1]
  1. Los Alamos National Laboratory
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
OSTI Identifier:
1000751
Report Number(s):
LA-UR-07-0276
TRN: US1100180
DOE Contract Number:
AC52-06NA25396
Resource Type:
Conference
Resource Relation:
Conference: STAIF 2007 CONFERENCE ; 200702 ; ALBUQUERQUE
Country of Publication:
United States
Language:
English
Subject:
22; BOUNDARY CONDITIONS; DESIGN; EVALUATION; NASA; NATURAL CONVECTION; PERFORMANCE; POWER INPUT; POWER REACTORS; POWER SYSTEMS; SHIELDING; SHIELDS; SPACE FLIGHT; THERMAL HYDRAULICS; WATER

Citation Formats

REID, ROBERT S., PEARSON, J. BOSIE, and STEWART, ERIC T.. EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR. United States: N. p., 2007. Web.
REID, ROBERT S., PEARSON, J. BOSIE, & STEWART, ERIC T.. EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR. United States.
REID, ROBERT S., PEARSON, J. BOSIE, and STEWART, ERIC T.. Tue . "EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR". United States. doi:. https://www.osti.gov/servlets/purl/1000751.
@article{osti_1000751,
title = {EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR},
author = {REID, ROBERT S. and PEARSON, J. BOSIE and STEWART, ERIC T.},
abstractNote = {Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jan 16 00:00:00 EST 2007},
month = {Tue Jan 16 00:00:00 EST 2007}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WSTmore » is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 deg. C. The CFD model with 1/6-g predicts a maximum water temperature of 88 deg. C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.« less
  • Water shielding is an attractive option for an affordable lunar surface fission reactor program. The attractiveness of the water shielding option arises from the relative ease of proto-typing and ground testing, the relatively low development effort needed, as well as the fabrication and operating experience with stainless steel and water. The most significant limitation in using a water shield is temperature: to prevent the formation of voids and the consequent loss of cooling, the water temperature has to be maintained below the saturation temperature corresponding to the shield pressure. This paper examines natural convection for a prototypic water shield designmore » using the computational fluid dynamics (CFD) code CFX-5 as well as analytical modeling. The results show that natural convection is adequate to keep the water well-mixed. The results also show that for the above-ground configuration, shield surface and water temperatures during lunar day conditions are high enough to require shield pressures up to 2.5 atm to prevent void formation. For the buried configuration, a set of ammonia heat pipes attached to the shield outer wall can be used to maintain water temperatures within acceptable limits. Overall the results show that water shielding is feasible for lunar surface applications. The results of the CFD analyses can also be used to guide development of testing plans for shield thermal testing. (authors)« less
  • The amount of electrical resistance in braze joints is not known for certain. In addition annealing processes that occurs during a braze or solder operation can change the residual resistivity ratio (RRR) of the copper. The change in the electrical resistivity of samples of copper because of exposure to conditions that a high current lead would see during a brazing operation were experimentally investigated. A sample was taken from a manufacturing and brazing trial of the high current power leads for the Superconducting Super Collider (SSC), and from oxygen free high conductivity copper (OFHC) 101 rod similar to that usedmore » in the trial. The samples were heated under conditions that a current lead would undergo during the brazing process. Measurements were made of the electrical resistance of the copper specimens and across abraze joint in the manufacturing trial sample for temperatures ranging from liquid helium to room temperature.« less
  • The amount of electrical resistance in braze joints is not known for certain. In addition annealing processes that occurs during a braze or solder operation can change the residual resistivity ratio (RRR) of the copper. The change in the electrical resistivity of samples of copper because of exposure to conditions that a high current lead would see during a brazing operation were experimentally investigated. A sample was taken from a manufacturing and brazing trial of the high current power leads for the Superconducting Super Collider (SSC), and from oxygen free high conductivity copper (OFHC) 101 rod similar to that usedmore » in the trial. The samples were heated under conditions that a current lead would undergo during the brazing process. Measurements were made of the electrical resistance of the copper specimens and across abraze joint in the manufacturing trial sample for temperatures ranging from liquid helium to room temperature.« less
  • This paper presents the segmentation of the moderator vessel and of the thermal shield of the MZFR research reactor by means of under water plasma and contact arc metal cutting. The moderator vessel and the thermal shield are the most essential parts of the reactor vessel internals. These components have been segmented in 2005 by means of remotely controlled under water cutting utilizing a special manipulator system, a plasma torch and CAMC (Contact Arc Metal Cutting) as cutting tools. The engineered equipment used is a highly advanced design developed in a two years R and D program. It was qualifiedmore » to cut through steel walls of more than 100 mm thickness in 8 meters water depth. Both the moderator vessel and the thermal shield had to be cut into such size that the segments could afterwards be packed into shielded waste containers each with a volume of roughly 1 m{sup 3}. Segmentation of the moderator vessel and of the thermal shield was performed within 15 months. (authors)« less