skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Evaluation of Iron Aluminide Weld Overlays for Erosion-Corrosion Resistant Boiler Tube Coatings in Low NOx Boilers

Abstract

Iron aluminide weld overlays containing ternary additions and thermal spray coatings are being investigated for corrosion protection of boiler tubes in Low NO{sub x} burners. The primary objective of the research is to identify overlay and thermal spray compositions that provide corrosion protection of waterwall boiler tubes.

Authors:
; ;
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Org.:
USDOE Office of Science (US)
OSTI Identifier:
757303
Report Number(s):
ORNL/Sub/95-SU604/03
TRN: AH200029%%30
DOE Contract Number:  
AC05-00OR22725
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 28 Apr 2000
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; 42 ENGINEERING; BOILERS; PROTECTIVE COATINGS; CORROSION PROTECTION; IRON ALLOYS; SPRAY COATING; TUBES; WELDED JOINTS; ALUMINIUM ALLOYS

Citation Formats

Regina, J R, Lim, M, Barbosa, N., DuPont, J.N., and Marder, A R. Evaluation of Iron Aluminide Weld Overlays for Erosion-Corrosion Resistant Boiler Tube Coatings in Low NOx Boilers. United States: N. p., 2000. Web. doi:10.2172/757303.
Regina, J R, Lim, M, Barbosa, N., DuPont, J.N., & Marder, A R. Evaluation of Iron Aluminide Weld Overlays for Erosion-Corrosion Resistant Boiler Tube Coatings in Low NOx Boilers. United States. https://doi.org/10.2172/757303
Regina, J R, Lim, M, Barbosa, N., DuPont, J.N., and Marder, A R. 2000. "Evaluation of Iron Aluminide Weld Overlays for Erosion-Corrosion Resistant Boiler Tube Coatings in Low NOx Boilers". United States. https://doi.org/10.2172/757303. https://www.osti.gov/servlets/purl/757303.
@article{osti_757303,
title = {Evaluation of Iron Aluminide Weld Overlays for Erosion-Corrosion Resistant Boiler Tube Coatings in Low NOx Boilers},
author = {Regina, J R and Lim, M and Barbosa, N., DuPont, J.N. and Marder, A R},
abstractNote = {Iron aluminide weld overlays containing ternary additions and thermal spray coatings are being investigated for corrosion protection of boiler tubes in Low NO{sub x} burners. The primary objective of the research is to identify overlay and thermal spray compositions that provide corrosion protection of waterwall boiler tubes.},
doi = {10.2172/757303},
url = {https://www.osti.gov/biblio/757303}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Apr 28 00:00:00 EDT 2000},
month = {Fri Apr 28 00:00:00 EDT 2000}
}