Construction and operation of the surface contaminant detector Mod II. [Non-radioactive contamination]
This report contains detailed construction and operating instructions, a parts list, and cost estimates for a surface contaminant detector. The instrument is sensitive to the condensible contaminant content of environments and has been used for monitoring industrial facilities where contaminant sensitive parts are processed.