Measurements of satellite refrigerator compressor power consumption and efficiency
Each of the thirty compressors installed around the ring and at switchyard is an oil-injected, two-stage, Mycom screw compressor, driven by either a 350 hp or 400 hp motor. The reader is referred to TM1198 by John Satti for a detailed description of these compressors and the associated equipment. Since the power consumed by these compressors is a major operating expense for our accelerator, we were interested in measuring the power consumption and efficiency of our compressors. Two compressors were studied in detail - one having a GE 350 hp motor (F0 No. 2) and one a new GE 400 hp high efficiency motor (F0 No. 1). Data were taken for each compressor with the high stage always fully loaded. These data and values calculated from the data are tabulated.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 6805521
- Report Number(s):
- FNAL-TM-1276; ON: DE84016724
- Resource Relation:
- Other Information: Portions are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
Similar Records
Test of an improved oil injected helium screw compressor at Fermilab
Performance of the 350 HP Sullair Oil Screw Compressor
Related Subjects
42 ENGINEERING
COMPRESSORS
EFFICIENCY
FERMILAB ACCELERATOR
ELECTRIC MOTORS
EXPERIMENTAL DATA
REFRIGERATORS
ACCELERATORS
CYCLIC ACCELERATORS
DATA
INFORMATION
MOTORS
NUMERICAL DATA
SYNCHROTRONS
430303* - Particle Accelerators- Experimental Facilities & Equipment
420200 - Engineering- Facilities
Equipment
& Techniques