skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: LOFT CIS analysis line 2''-LS-120-AB outside containment penetration S-1A

Technical Report ·
DOI:https://doi.org/10.2172/6797560· OSTI ID:6797560

Line 2''-LS-120-AB outside containment penetration S-1A was analyzed to ASME Section III, Subsection NC (Class 2) criteria. The line is part of the LOFT Containment Isolation System. The model considered the line from the penetration outward through the second isolation valve. Results of the analysis show that this section of the line meets Class 2 requirements without modification.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
6797560
Report Number(s):
LTR-137-1; TRN: 79-002028
Country of Publication:
United States
Language:
English