skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Spectrochemical determination of tantalum in plutonium metal using direct current plasma emission spectrometry

Abstract

Tantalum is determined by direct current plasma spectrometry after separation of plutonium from solution as PuF/sub 3/. After centrifugation of the PuF/sub 3/ precipitate, a low level of plutonium remains in solution in sufficient quantity to cause spectral interferences. It is necessary to determine the plutonium by dc plasma spectrometry and apply a correction to determine low tantalum concentrations with good accuracy and precision. Tantalum can be determined down to 0.4 ppM in solution with a relative standard deviation of 10 percent. Better precision can be achieved at higher concentrations. The procedure is simple and convenient for glovebox work. 5 references, 1 figure, 1 table.

Authors:
;
Publication Date:
Research Org.:
Lawrence Livermore National Lab., CA (USA)
OSTI Identifier:
5484018
Report Number(s):
UCRL-90102; CONF-8311119-1
ON: DE84004360
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Conference
Resource Relation:
Conference: Pu isotopic and metals exchange meeting, Miamisburg, OH, USA, 2 Nov 1983
Country of Publication:
United States
Language:
English
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; PLUTONIUM; CHEMICAL ANALYSIS; TANTALUM; EMISSION SPECTROSCOPY; ACCURACY; SENSITIVITY; ACTINIDES; ELEMENTS; METALS; SPECTROSCOPY; TRANSITION ELEMENTS; TRANSURANIUM ELEMENTS; 400104* - Spectral Procedures- (-1987)

Citation Formats

Fadeff, S K, and Morris, W F. Spectrochemical determination of tantalum in plutonium metal using direct current plasma emission spectrometry. United States: N. p., 1983. Web.
Fadeff, S K, & Morris, W F. Spectrochemical determination of tantalum in plutonium metal using direct current plasma emission spectrometry. United States.
Fadeff, S K, and Morris, W F. 1983. "Spectrochemical determination of tantalum in plutonium metal using direct current plasma emission spectrometry". United States. https://www.osti.gov/servlets/purl/5484018.
@article{osti_5484018,
title = {Spectrochemical determination of tantalum in plutonium metal using direct current plasma emission spectrometry},
author = {Fadeff, S K and Morris, W F},
abstractNote = {Tantalum is determined by direct current plasma spectrometry after separation of plutonium from solution as PuF/sub 3/. After centrifugation of the PuF/sub 3/ precipitate, a low level of plutonium remains in solution in sufficient quantity to cause spectral interferences. It is necessary to determine the plutonium by dc plasma spectrometry and apply a correction to determine low tantalum concentrations with good accuracy and precision. Tantalum can be determined down to 0.4 ppM in solution with a relative standard deviation of 10 percent. Better precision can be achieved at higher concentrations. The procedure is simple and convenient for glovebox work. 5 references, 1 figure, 1 table.},
doi = {},
url = {https://www.osti.gov/biblio/5484018}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Dec 01 00:00:00 EST 1983},
month = {Thu Dec 01 00:00:00 EST 1983}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: