A FLYING WIRE SYSTEM IN THE AGS.
Conference
·
OSTI ID:15016649
As the AGS prepares to serve as the injector for RHIC, monitoring and control of the beam transverse emittance become a major and important topic. Before the installation of the flying wire system, the emittance was measured with ionization profile monitors in the AGS, which require correction for space charge effects. It is desirable to have a second means of measuring profile that is less depend on intensity. A flying wire system has been installed in the AGS recently to perform this task. This paper discusses the hardware and software setup and the capabilities of the system.
- Research Organization:
- BROOKHAVEN NATIONAL LABORATORY (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 15016649
- Report Number(s):
- BNL-65923; R&D Project: AD2ADOP; KA0201; TRN: US0502780
- Resource Relation:
- Conference: 1999 PARTICLE ACCELERATOR CONFERENCE, NEW YORK, NY (US), 03/29/1999--04/02/1999; Other Information: PBD: 29 Mar 1999
- Country of Publication:
- United States
- Language:
- English