skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: 2014 AFCI Glovebox Event Executive Summary

Technical Report ·
DOI:https://doi.org/10.2172/1260448· OSTI ID:1260448
 [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)

One of the primary INL missions is to support development of advanced fuels with the goal of creating reactor fuels that produce less waste and are easier to store. The Advanced Fuel Cycle Initiative (AFCI) Glovebox in the Fuel Manufacturing Facility (FMF) is used for several fuel fabrication steps that involve transuranic elements, including americium. The AFCI glove box contains equipment used for fuel fabrication, including an arc melter – a small, laboratory-scale version of an electric arc furnace used to make new metal alloys for research – and an americium distillation apparatus. This overview summarizes key findings related to the investigation into the releases of airborne radioactivity that occurred in the AFCI glovebox room in late August and early September 2014. The full report (AFCI Glovebox Radiological Release – Evaluation, Corrective Actions and Testing, INL/INL-15-36996) provides details of the identified issues, corrective actions taken as well as lessons learned

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1260448
Report Number(s):
INL/EXT-16-37638; TRN: US1601544
Country of Publication:
United States
Language:
English