Title: Evaluation of methods to measure surface level in waste storage tanks

Technical Report ·
DOI:https://doi.org/10.2172/10164645· OSTI ID:10164645

This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. Test were performed with five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{sup {trademark}} 872 Radar Gauge, the Enraf-Nonius{sup {trademark}} 854 Advanced Technology Gauge, the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{sup {reg_sign}} Precision Level Gauge, and the Micro Switch 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
10164645
Report Number(s):
PNL-8687; ON: DE93016046
Resource Relation:
Other Information: PBD: Jun 1993
Country of Publication:
United States
Language:
English