Title: Annular Flow Distribution test. Final report

Technical Report ·
DOI:https://doi.org/10.2172/10163777· OSTI ID:10163777
 [1]; ; ; ;  [2]
  1. ed.; Westinghouse Savannah River Co., Aiken, SC (United States)
  2. Babcock and Wilcox Co., Alliance, OH (United States). Research Center

This report documents the Babcock and Wilcox (B&W) Annular Flow Distribution testing for the Savannah River Laboratory (SRL). The objective of the Annular Flow Distribution Test Program is to characterize the flow distribution between annular coolant channels for the Mark-22 fuel assembly with the bottom fitting insert (BFI) in place. Flow rate measurements for each annular channel were obtained by establishing ``hydraulic similarity`` between an instrumented fuel assembly with the BFI removed and a ``reference`` fuel assembly with the BFI installed. Empirical correlations of annular flow rates were generated for a range of boundary conditions.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
10163777
Report Number(s):
WSRC-TR-90-551; ON: DE92018135
Resource Relation:
Other Information: PBD: Dec 1990
Country of Publication:
United States
Language:
English