Title: The role of heating and current drive in ITER

Conference ·
OSTI ID:10154537

This report discusses and summarize the role of heating and non-inductive current drive in ITER as: (1) ITER must have heating power sufficient for ignition. (2) The heating system must be capable of current drive. (3) Steady-state operation is an ``ultimate goal.`` It is recognized that additional heating and current drive power (beyond what is initially installed on ITER) may be required. (4) The ``Ultimate goal of steady-state operation`` means steady-state with Q{sub CD} {ge} 5. Unlike the ``Terms of Reference`` for the ITER CDA, the ``ITER Technical Objectives and Approaches`` for the EDA sets no goal for the neutron wall load during steady-state operation. (5) In addition to bulk current drive, the ITER heating and current drive system should be used for current profile control and for burn control.

Research Organization:
Lawrence Livermore National Lab., CA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
10154537
Report Number(s):
UCRL-JC-115423; CONF-9310322-1; ON: DE94012679; TRN: 94:012082
Resource Relation:
Conference: International thermonuclear experimental reactor radio frequency technical meeting,Garching (Germany),21-27 Oct 1993; Other Information: PBD: 18 Oct 1993
Country of Publication:
United States
Language:
English