skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Corrosion testing of Type 304L stainless steel for waste tank applications

Conference ·
OSTI ID:10133389

AISI Type 304L stainless steel will be the material of construction for hazardous waste storage tanks. The corrosion behavior of 304L was characterized in simulated waste solutions using potentiodynamic polarization, electrochemical impedance spectroscopy and long term immersion tests. The results were correlated to assess the use of corrosion characteristics determined by electrochemical techniques for predicting long term corrosion behavior. The corrosion behaviors of Type A537 carbon steel and Incoloy 825 were also evaluated. A good correlation was found between the results from the electrochemical techniques and the immersion tests.

Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
10133389
Report Number(s):
WSRC-MS-90-317; CONF-911179-4; ON: DE92010097
Resource Relation:
Conference: Life prediction of corrodible structures,Kauai, HI (United States),5-8 Nov 1991; Other Information: PBD: [1991]
Country of Publication:
United States
Language:
English