skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Determination of process conditions for the spray nozzle for the DWPF melter off-gas HEME

Technical Report ·
DOI:https://doi.org/10.2172/10107468· OSTI ID:10107468

The DWPF melter off-gas systems have High Efficiency Mist Eliminators (HEME) upstream of the High Efficiency Particulates Air filters (HEPA) to remove fine mist and particulates from the off-gas. To have an acceptable filter life and an efficient HEME operation, air atomized water is sprayed into the melter off-gas and onto the HEME surface. The water spray keeps the HEME wet, which dissolves the soluble particulates and enhances the HEME efficiency. DWPF Technical requested SRL to determine the conditions for the DWPF nozzle which will give complete atomization of water so that the HEME will operate efficiently. Since the air pressure and flow rate to generate the desired spray are not known before hand, an experiment was performed in two stages. The first stage involved preliminary tests which mapped out a general operating region for producing the desired spray pattern. Afterward, all the gages and meters were changed to suitable ranges for the conditions which generated an acceptable spray. This report summarizes the results and the conclusions of the second stage experiment.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
10107468
Report Number(s):
WSRC-RP-91-1215; ON: DE93003322
Resource Relation:
Other Information: PBD: 15 Dec 1991
Country of Publication:
United States
Language:
English