During the accelerator studies period of 12/90 through 1/91 the Accumulator BPM system was investigated in some detail in an effort to improve its reliability and accuracy in making closed orbit measurements. The motivation for this is to try and improve the beam energy resolution for E760. The relativistic {beta} of the {bar p} is given by {beta} = f{sub R}L/c where f{sub R} is the revolution frequency, L is the orbit length ({approx} 474050mm), and c is the speed of light. Hence, the error in {beta} is given by d{beta}/{beta} = df{sub R}/f{sub R} + dL/L. Since df{sub R}/f{sub R} is {approx} 2 x 10{sup -7}, the main contribution to the error comes from dL. During the E760 run of 5/90 to 9/90 dL was estimated to be {approx} 1mm. It is thought that this can be reduced to {approx} .25mm with proper use of the present BPM system. L is given by L = L{sub 0} + {delta}L where L{sub 0} is the accurately known orbit length of a reference orbit (extracted from an energy scan of the J/{Psi} or {Psi}{prime}), and {delta}L is the difference orbit between the current orbit and the reference orbit. SL is calculated in the 1st approximation by {delta}L = {Sigma}{sub i}C{sub i}{Sigma}{sub j}{Delta}BPM{sub ij} where {Delta}BPM{sub ij} is the horizontal difference orbit at the ith BPM in the jth sector and C{sub i} are constants depending upon the location of the BPM pickup and the strength of the quadrupoles. Table I lists the constants C{sub i}, and Fig. 1 shows a typical difference orbit, {Delta}BPM{sub ij}. These studies were all done with 'reverse protons' and concentrated on closed orbit measurements with the Accumulator horizontal BPMs. The low frequency (H=2) mode of the BPM system is used in all cases, therefore it is required that the beam be bunched with ARF3 at some level. The low frequency RF module in the BPM system had previously been modified to track the H=2 frequency.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
983980
Report Number(s):
FERMILAB-PBAR-NOTE-501; oai:inspirehep.net:862293; TRN: US201015%%1040
Country of Publication:
United States
Language:
English

Similar Records

L'energie sombre: Un mirage cosmique? Luminosity distance {ne} proper distance: A cosmological dissimilitude induced by nonlinear electrodynamics
Journal Article · Wed Jun 23 00:00:00 EDT 2010 · AIP Conference Proceedings · OSTI ID:983980

Rotational partition functions for symmetric-top molecules
Journal Article · Wed Aug 15 00:00:00 EDT 1990 · Journal of Chemical Physics; (USA) · OSTI ID:983980

Application of some operations research techniques to food chain analysis problems
Journal Article · Fri Jan 01 00:00:00 EST 1965 · Health Phys.; (United States) · OSTI ID:983980