Benchmark specifications and data requirements for initial modeling of the China experimental fast reactor.
A specification is proposed for an initial transient benchmark analysis of the China Experimental Fast Reactor design based on the analysis capabilities of the SAS4A/SASSYS-1 code. For the initial benchmark, a single-channel protected transient overpower accident is defined. Reactivity feedback coefficients will not be required and simplified material properties are recommended. This report also describes the data required for developing the modeling input. This data includes assembly geometry, reactor power distributions, kinetics and decay heat data, and material properties. Comparisons of benchmark results will take place at a future SAS4A/SASSYS-1 training meeting planned to occur at Argonne National Laboratory. Future benchmark specifications will be planned to expand upon this initial model to include more complex reactivity feedback models, material properties, additional assembly geometry, and primary and intermediate coolant systems.
- Research Organization:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Organization:
- NE
- DOE Contract Number:
- DE-AC02-06CH11357
- OSTI ID: