Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report
Abstract
This report documents the development of an air-source integrated heat pump (AS-IHP) through the third quarter of FY2007. It describes the design, analyses and testing of the AS-IHP, and provides performance specifications for a field test prototype and proposed control strategy. The results obtained so far continue to support the AS-IHP being a promising candidate to meet the energy service needs for DOE's development of a Zero Energy Home (ZEH) by the year 2020.
- Authors:
-
- ORNL
- Publication Date:
- Research Org.:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center (BTRIC)
- Sponsoring Org.:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE)
- OSTI Identifier:
- 971208
- Report Number(s):
- ORNL/TM-2007/112
BT0302000; CEBT002; TRN: US201004%%427
- DOE Contract Number:
- DE-AC05-00OR22725
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; DESIGN; FIELD TESTS; HEAT PUMPS; PERFORMANCE; SPECIFICATIONS; TESTING; ENERGY EFFICIENCY; HOUSES
Citation Formats
Murphy, Richard W, Rice, C Keith, Baxter, Van D, and Craddick, William G. Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report. United States: N. p., 2007.
Web. doi:10.2172/971208.
Murphy, Richard W, Rice, C Keith, Baxter, Van D, & Craddick, William G. Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report. United States. https://doi.org/10.2172/971208
Murphy, Richard W, Rice, C Keith, Baxter, Van D, and Craddick, William G. 2007.
"Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report". United States. https://doi.org/10.2172/971208. https://www.osti.gov/servlets/purl/971208.
@article{osti_971208,
title = {Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report},
author = {Murphy, Richard W and Rice, C Keith and Baxter, Van D and Craddick, William G},
abstractNote = {This report documents the development of an air-source integrated heat pump (AS-IHP) through the third quarter of FY2007. It describes the design, analyses and testing of the AS-IHP, and provides performance specifications for a field test prototype and proposed control strategy. The results obtained so far continue to support the AS-IHP being a promising candidate to meet the energy service needs for DOE's development of a Zero Energy Home (ZEH) by the year 2020.},
doi = {10.2172/971208},
url = {https://www.osti.gov/biblio/971208},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Jul 01 00:00:00 EDT 2007},
month = {Sun Jul 01 00:00:00 EDT 2007}
}