skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Directional Detection of Fast Neutrons Using a Time Projection Chamber

Conference ·

Spontaneous fission in Special Nuclear Material (SNM) such as plutonium and highly enriched uranium (HEU) results in the emission of neutrons with energies in the MeV range (hereafter 'fast neutrons'). These fast neutrons are largely unaffected by the few centimeters of intervening high-Z material that would suffice for attenuating most emitted gamma rays, while tens of centimeters of hydrogenous materials are required to achieve substantial attenuation of neutron fluxes from SNM. Neutron detectors are therefore an important complement to gamma-ray detectors in SNM search and monitoring applications. The rate at which SNM emits fast neutrons varies from about 2 per kilogram per second for typical HEU to some 60,000 per kilogram per second for metallic weapons grade plutonium. These rates can be compared with typical sea-level (cosmogenic) neutron backgrounds of roughly 5 per second per square meter per steradian in the relevant energy range [1]. The fact that the backgrounds are largely isotropic makes directional neutron detection especially attractive for SNM detection. The ability to detect, localize, and ultimately identify fast neutron sources at standoff will ultimately be limited by this background rate. Fast neutrons are particularly well suited to standoff detection and localization of SNM or other fast neutrons sources. Fast neutrons have attenuation lengths of about 60 meters in air, and retain considerable information about their source direction even after one or two scatters. Knowledge of the incoming direction of a fast neutron, from SNM or otherwise, has the potential to significantly improve signal to background in a variety of applications, since the background arriving from any one direction is a small fraction of the total background. Imaging or directional information therefore allows for source detection at a larger standoff distance or with shorter dwell times compared to nondirectional detectors, provided high detection efficiency can be maintained. Directional detection of neutrons has been previously considered for applications such as controlled fusion neutron imaging [2], nuclear fuel safety research [3], imaging of solar neutrons and SNM [4], and in nuclear science [5]. The use of scintillating crystals and fibers has been proposed for directional neutron detection [6]. Recently, a neutron scatter camera has been designed, constructed, and tested for imaging of fast neutrons, characteristic for SNM material fission [7]. The neutron scatter camera relies on the measurement of the proton recoil angle and proton energy by time of flight between two segmented solid-state detectors. A single-measurement result from the neutron scatter camera is a ring containing the possible incident neutron direction. Here we describe the development and commissioning of a directional neutron detection system based on a time projection chamber (TPC) detector. The TPC, which has been widely used in particle and nuclear physics research for several decades, provides a convenient means of measuring the full 3D trajectory, specific ionization (i.e particle type) and energy of charged particles. For this application, we observe recoil protons produced by fast neutron scatters on protons in hydrogen or methane gas. Gas pressures of a few ATM provide reasonable neutron interaction/scattering rates.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
964522
Report Number(s):
LLNL-CONF-413682; TRN: US0903867
Resource Relation:
Journal Volume: 624; Journal Issue: 1; Conference: Presented at: INMM Annual Meeting, Tucson, AZ, United States, Jul 12 - Jul 16, 2009
Country of Publication:
United States
Language:
English

References (18)

Measurement of the flux and energy spectrum of cosmic-ray induced neutrons on the ground journal December 2004
The effects of a hydrogen environment on the lifetime of small-diameter drift chamber anode wires
  • Smith, T.; Kunkle, J.; Castelaz, J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 550, Issue 1-2 https://doi.org/10.1016/j.nima.2005.06.023
journal September 2005
Directional Neutron Detection Using a Time Projection Chamber journal June 2009
Neutron imaging camera conference May 2008
A background-free direction-sensitive neutron detector
  • Roccaro, Alvaro; Tomita, H.; Ahlen, S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 608, Issue 2 https://doi.org/10.1016/j.nima.2009.06.102
journal September 2009
Comptel measurements of solar flare neutrons journal September 1993
The Time Projection Chamber journal October 1978
Study of high-pressure hydrogen-operated wire chambers designed for a precision measurement of the singlet μp capture rate
  • Maev, E. M.; Andreev, V. A.; Case, T. A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 478, Issue 1-2 https://doi.org/10.1016/S0168-9002(01)01741-7
journal February 2002
Development and performance of a high pressure hydrogen time projection chamber journal June 1982
Feasibility tests of a high resolution sampling radial drift chamber
  • Huth, John; Nygren, David
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 241, Issue 2-3 https://doi.org/10.1016/0168-9002(85)90589-3
journal December 1985
Properties and performance of the prototype instrument for the Pierre Auger Observatory
  • Abraham, J.; Aglietta, M.; Aguirre, I. C.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 523, Issue 1-2 https://doi.org/10.1016/j.nima.2003.12.012
journal May 2004
Sudbury neutrino observatory neutral current detector acquisition software overview journal June 2004
Monte Carlo simulation of electron drift and diffusion in counting gases under the influence of electric and magnetic fields journal January 1999
An analytical approximation of depth - dose distributions for therapeutic proton beams journal August 1996
Fast Hough-transform track reconstruction for the ALICE TPC journal October 2006
The content of 250Cf and 248Cm in 252Cf neutron sources and the effect on the neutron emission rate journal May 2007
Thick GEM-like hole multipliers: properties and possible applications
  • Chechik, R.; Breskin, A.; Shalem, C.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 535, Issue 1-2 https://doi.org/10.1016/j.nima.2004.07.138
journal December 2004
MCNP-PoliMi: a Monte-Carlo code for correlation measurements
  • Pozzi, Sara A.; Padovani, Enrico; Marseguerra, Marzio
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 513, Issue 3 https://doi.org/10.1016/j.nima.2003.06.012
journal November 2003