Characteristics of Yerevan High Transparency Scintillators
Optical transmission, light output and time characteristics are given for long scintillator strips fabricated at the Yerevan Physics Institute using the extrusion method. It is shown that at 45% relative (to anthracene) light output, good transmission (2.5/2.9 m attenuation length with photomultiplier direct readout and 3/3.5 m attenuation length fiber readout) and time characteristics (average decay time 2.8 nsec) were obtained.