Higher Order Model Power Calculation of the 56 MHz SRF Cavity
In this report, the HOM power dissipated to the load in the 56 MHz RF cavity is calculated. The HOM frequencies and Q factors with the inserted HOM damper are obtained from the simulations by MWS and SLAC codes.