Intial synchroscan streak camera imaging at the A0 photoinjector
At the Fermilab A0 photoinjector facility, bunch-length measurements of the laser micropulse and the e-beam micropulse have been done in the past with a single-sweep module of the Hamamatsu C5680 streak camera with an intrinsic shot-to-shot trigger jitter of 10 to 20 ps. We have upgraded the camera system with the synchroscan module tuned to 81.25 MHz to provide synchronous summing capability with less than 1.5-ps FWHM trigger jitter and a phase-locked delay box to provide phase stability of {approx}1 ps over 10s of minutes. This allowed us to measure both the UV laser pulse train at 244 nm and the e-beam via optical transition radiation (OTR). Due to the low electron beam energies and OTR signals, we typically summed over 50 micropulses with 1 nC per micropulse. We also did electron beam bunch length vs. micropulse charge measurements to identify a significant e-beam micropulse elongation from 10 to 30 ps (FWHM) for charges from 1 to 4.6 nC. This effect is attributed to space-charge effects in the PC gun as reproduced by ASTRA calculations. Chromatic temporal dispersion effects in the optics were also characterized and will be reported.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 928098
- Report Number(s):
- FERMILAB-CONF-08-107-AD; TRN: US0804586
- Resource Relation:
- Conference: Presented at 13th Beam Instrumentation Workshop (BIW08), Lake Tahoe, California, 4-8 May 2008
- Country of Publication:
- United States
- Language:
- English
Similar Records
Laser Timing Jitter Measurements using a Dual-Sweep Streak Camera at the A0 Photoinjector
Initial Observations of Micropulse Elongation of Electron Beams in a SCRF Accelerator