skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Review of the Physical Science Facility Stack Air Sampling Probe Locations

Abstract

This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.

Authors:
Publication Date:
Research Org.:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
927983
Report Number(s):
PNNL-16864
39NN21000; TRN: US200816%%934
DOE Contract Number:  
AC05-76RL01830
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; AIR POLLUTION MONITORING; PROBES; RECOMMENDATIONS; SAMPLING; STACKS; AIR SAMPLERS; POSITIONING; ANSI N13.1, Air Sampling, Sample Probe

Citation Formats

Glissmeyer, John A. Review of the Physical Science Facility Stack Air Sampling Probe Locations. United States: N. p., 2007. Web. doi:10.2172/927983.
Glissmeyer, John A. Review of the Physical Science Facility Stack Air Sampling Probe Locations. United States. https://doi.org/10.2172/927983
Glissmeyer, John A. 2007. "Review of the Physical Science Facility Stack Air Sampling Probe Locations". United States. https://doi.org/10.2172/927983. https://www.osti.gov/servlets/purl/927983.
@article{osti_927983,
title = {Review of the Physical Science Facility Stack Air Sampling Probe Locations},
author = {Glissmeyer, John A},
abstractNote = {This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.},