Integrated Efficiency Test for Pyrochemical Fuel Cycles
Conference
·
OSTI ID:923480
An integrated efficiency test was conducted with sodium bonded, spent EBR-II drive fuel elements. The major equipment involved in the test were the element chopper, Mk-IV electrorefiner, cathode processor, and casting furnace. Four electrorefining batches (containing 54.4 kg heavy metal) were processes under the fixed operating parameters that have been developed for this equipment based on over a decade’s worth of processing experience. A mass balance across this equipment was performed. Actinide dissolution and recovery efficiencies were established based on the mass balance and chemical analytical results of various samples taken from process streams during the integrated efficiency test.
- Research Organization:
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- DOE - NE
- DOE Contract Number:
- DE-AC07-99ID-13727
- OSTI ID:
- 923480
- Report Number(s):
- INL/CON-07-12076; TRN: US0801842
- Resource Relation:
- Conference: Global 2007,Boise, ID,09/09/2007,09/13/2007
- Country of Publication:
- United States
- Language:
- English
Similar Records
Integrated Efficiency Test for Pyrochemical Fuel Cycles
Integrated Efficiency Test for Pyrochemical Fuel Cycles
Integrated Electrorefining Efficiency Test for Pyrochemical Fuel Cycle
Journal Article
·
Fri May 01 00:00:00 EDT 2009
· Journal of Nuclear Technology
·
OSTI ID:923480
+3 more
Integrated Efficiency Test for Pyrochemical Fuel Cycles
Conference
·
Sun Jul 01 00:00:00 EDT 2007
·
OSTI ID:923480
+3 more
Integrated Electrorefining Efficiency Test for Pyrochemical Fuel Cycle
Conference
·
Wed Nov 01 00:00:00 EST 2006
·
OSTI ID:923480
+2 more