Title: TREATABILITY TEST FOR REMOVING TECHNETIUM-99 FROM 200-ZP-1 GROUNDWATER HANFORD SITE

Conference ·
OSTI ID:920387

The 200-ZP-1 Groundwater Operable Unit (OU) is one of two groundwater OUs located within the 200 West groundwater aggregate area of the Hanford Site. The primary risk-driving contaminants within the 200-ZP-1 OU include carbon tetrachloride and technetium-99 (Tc-99). A pump-and-treat system for this OU was initially installed in 1995 to control the 0.002 kg/m{sup 3} (2000 {micro}g/L) contour of the carbon tetrachloride plume. Carbon tetrachloride is removed from groundwater with the assistance of an air-stripping tower. Ten extraction wells and three injection wells operate at a combined rate of approximately 0.017m{sup 3}/s (17.03 L/s). In 2005, groundwater from two of the extraction wells (299-W15-765 and 299-W15-44) began to show concentrations greater than twice the maximum contaminant level (MCL) of Tc-99 (33,309 beq/m{sup 3} or 900 pCi/L). The Tc-99 groundwater concentrations from all ten of the extraction wells when mixed were more than one-half of the MCL and were slowly increasing. If concentrations continued to rise and the water remained untreated for Tc-99, there was concern that the water re-injected into the aquifer could exceed the MCL standard. Multiple treatment technologies were reviewed for selectively removing Tc-99 from the groundwater. Of the treatment technologies, only ion exchange was determined to be highly selective, commercially available, and relatively low in cost. Through research funded by the U.S. Department of Energy, the ion-exchange resin Purolite{reg_sign} A-530E was found to successfully remove Tc-99 from groundwater, even in the presence of competing anions. For this and other reasons, Purolite{reg_sign} A-530E ion exchange resin was selected for treatability testing. The treatability test required installing resin columns on the discharge lines from extraction wells 299-W15-765 and 299-W15-44. Preliminary test results have concluded that the Purolite{reg_sign} A-530E resin is effective at removing Tc-99 from groundwater to below detection limits even in the presence of competing anions (e.g., nitrate and sulfate) at concentrations five to six magnitudes higher than Tc-99.

Research Organization:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Organization:
USDOE - Office of Environmental Management (EM)
DOE Contract Number:
DE-AC06-96RL13200
OSTI ID:
920387
Report Number(s):
SGW-35753-FP Rev 0; TRN: US200818%%894
Resource Relation:
Conference: WASTE MANAGEMENT SYMPOSIA (WM08) 02/24/2008 THRU 02/28/2008 PHOENIX AZ
Country of Publication:
United States
Language:
English