skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Design and Implementation of the New D0 Level-1 Calorimeter Trigger

Journal Article ·
OSTI ID:919091

Increasing luminosity at the Fermilab Tevatron collider has led the D0 collaboration to make improvements to its detector beyond those already in place for Run IIa, which began in March 2001. One of the cornerstones of this Run IIb upgrade is a completely redesigned level-1 calorimeter trigger system. The new system employs novel architecture and algorithms to retain high efficiency for interesting events while substantially increasing rejection of background. We describe the design and implementation of the new level-1 calorimeter trigger hardware and discuss its performance during Run IIb data taking. In addition to strengthening the physics capabilities of D0, this trigger system will provide valuable insight into the operation of analogous devices to be used at LHC experiments.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-07CH11359
OSTI ID:
919091
Report Number(s):
FERMILAB-PUB-07-492-E; arXiv eprint number arXiv:0709.3750; TRN: US0806307
Country of Publication:
United States
Language:
English

Similar Records

Di-J/Ψ Studies, Level 3 Tracking and the D0 Run IIb Upgrade
Thesis/Dissertation · Mon Feb 01 00:00:00 EST 2010 · OSTI ID:919091

The D0 calorimeter trigger
Conference · Tue Dec 01 00:00:00 EST 1992 · OSTI ID:919091

The D0 calorimeter trigger
Conference · Tue Dec 01 00:00:00 EST 1992 · OSTI ID:919091