Title: Low-Temperature, Vacuum-Aided Thermal Desorption Studies on a Simulated Organic Sludge Waste

Technical Report ·
DOI:https://doi.org/10.2172/910974· OSTI ID:910974

This report describes an initial set of small scale lab tests conducted on surrogate waste materials to investigate mass release behavior of volatile organics (VOC’s) from a solidified liquid organic sludge matrix under vacuumaided, low-temperature thermal desorption conditions. Low temperature thermal desorption is being considered as a potential processing technology alternative to incineration, to remove gas generation limitations affecting the transportation of transuranic (TRU) contaminated organic sludge wastes to a designated off-site repository (i.e., the Waste Isolation Pilot Plant). The lab-scale tests provide initial exploratory level information on temperature profiles and rates of volatile organic desorption for a range of initial VOC/oil liquid mixture concentrations in a calcium silicate matrix, under low temperature heating and vacuum boundary conditions that are representative of potentially desirable “in-drum desorption” conditions. The results of these tests indicate that reduced operating pressures have a potential for significantly enhancing the rate of thermal desorption experienced from a liquid organic/oil solidified “sludge” waste. Furthermore, the results indicate that in-drum thermal desorption can be performed on organic sludge wastes, at reduced pressures, while maintaining an operating temperature sufficiently low to prevent destruction of the waste drum packaging materials (confinement) surrounding the waste. The results also indicate that VOC release behavior/rates in the vacuum thermal desorption process cannot be represented by a simple liquid-liquid mass-diffusion model, since overall mass release rates observed are generally two orders of magnitude greater than predicted by simple liquid-liquid mass diffusion. This is partially attributed to the effects of the transient temperature profiles within the sludge during heat up; however, the primary cause is thought to be micro boiling of the volatile organics within the simulated sludge. Micro boiling of VOC’s would be expected to occur in localized volumes within the organic sludge where temperatures exceed the volatile organic saturation temperature sufficiently to form vapor bubbles. Further model based evaluations reflecting the transient temperatures, local boiling, and subsequent vapor in liquid/sludge transport conditions are needed, with supporting controlled testing of the vacuum-aided thermal desorption process at small and full-scale conditions in order to fully develop this process.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
DOE - EM
DOE Contract Number:
DE-AC07-99ID-13727
OSTI ID:
910974
Report Number(s):
INEEL/EXT-02-01076; TRN: US0704320
Country of Publication:
United States
Language:
English