Subtask 1.15-Passive Diffusion Sample Bags Made from Expanded Polytetrafluorethylene (ePTFE) to Measure VOC Concentrations in Groundwater
With laboratory testing of expanded polytetrafluoroethylene (ePTFE) membranes complete, collected data support that volatile organic compound (VOC) molecules will readily diffuse across ePTFE membranes. Membrane samples, supplied by BHA Technologies (GE Osmonics), were tested to determine diffusion rates for VOCs in groundwater. Tests were conducted using membranes with two different pore sizes, with and without thermally laminated spun bond backing, and multiple concentrations of contaminated groundwater. Results suggest that typical residence times associated with traditional samplers constructed of polyethylene (2 weeks) can be reduced by 1 week using ePTFE membranes (reducing project costs) and that VOCs will diffuse more readily at lower temperatures (2.2-3.3 C) across ePTFE materials.