Title: Pulsed power supply for PAR injection/extraction septum magnet

Technical Report ·
DOI:https://doi.org/10.2172/90661· OSTI ID:90661

A 22.5 {mu}H, 22.5 m{Omega} transformer septum magnet must be pulsed at a 60 Hz rate to inject beam from a 450 MeV positron linac into a positron accumulator ring (PAR) and to extract beam from it. Of the 60 pulses per second the first 24 are used for injection and the 30th for extraction. The 25th through the 29th are not used. This pattern is repeated continuously. A design study was performed of the power supply proposed in the APS Title I design. This supply produces a pulse that is approximately a half-sine-wave with a base width of approximately 1/3 ms; its peak current is adjustable from 3.5kA to 4.7kA and is repeatable within {+-}0.05%. The septum steel is reset by a half-sine pulse of reverse polarity a few milliseconds after the forward current pulse. No beam is present during reset. The use of the transformer design minimizes the cost of the capacitors used for energy storage.

Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
90661
Report Number(s):
LS-159; ON: DE95015570; TRN: 95:006169
Resource Relation:
Other Information: PBD: 23 Sep 1990
Country of Publication:
United States
Language:
English

Similar Records

Pulsed power supply for three APS septum magnets
Technical Report · Sun Mar 24 00:00:00 EST 1991 · OSTI ID:90661

Circuit description of the power systems for pulsed septum magnets at APS
Conference · Tue Jan 01 00:00:00 EST 1991 · OSTI ID:90661

A pulsed septum magnet for the APS
Conference · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:90661