skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Failure analysis report: Heat exchanger tubes geothermal binary power plant, Magma Electric Company, East Mesa, California

Technical Report ·
DOI:https://doi.org/10.2172/895636· OSTI ID:895636

Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.

Research Organization:
Radian Corporation, Austin, TX
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC03-81SF11503
OSTI ID:
895636
Report Number(s):
Radian-82-002; DCN 82-212-011-33; TRN: US200703%%250
Country of Publication:
United States
Language:
English