skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Dose Rate Calculations for the 2-MCO/2-DHLW Waste Package

Technical Report ·
DOI:https://doi.org/10.2172/893799· OSTI ID:893799

The objective of this calculation is to determine the dose rates on the external surfaces of the waste package (WP) containing two Hanford defense high-level waste (DHLW) glass canisters and two Hanford multi-canister overpacks (MCO). Each MCO is loaded with the N Reactor spent nuclear fuel (SNF). The information provided by the sketches attached to this calculation is that of the potential design for the WP type considered in this calculation. The scope of this calculation is limited to reporting dose rates averaged over segments of the WP radial and axial surfaces and of surfaces 1 m and 2 m from the WP. The results of this calculation will be used to assess the shielding performance of the 2-MC012-DHLW WP engineering design.

Research Organization:
Yucca Mountain Project, Las Vegas, NV (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
NA
OSTI ID:
893799
Report Number(s):
CAL-DDC-NU-000002 Rev. 00; MOL.20001016.0006, DC# 25516; TRN: US0606122
Country of Publication:
United States
Language:
English