Title: The Effect of Solution Annealing on Alloy 22 Weld Properties

Conference ·
OSTI ID:887277

The effect of solution annealing temperature on the microstructure and observed corrosion attack mode in Alloy 22 welds was assessed. Specimens were examined in the as-welded state as well as solution annealed for 20 minutes at temperatures ranging from 1075 C to 1300 C. The microstructures of the specimens were first mapped using electron backscatter diffraction to determine the grain structure evolution due to solution annealing. Full recrystallization of the fusion zone was only observed in the 1200 C and 1300 C specimens, although the 1300 C specimen showed abnormal grain growth. As-welded, 1121 C and 1200 C specimens were also subjected to electrochemical testing in a 6 molal NaCl + 0.9 molal KNO{sub 3} environment to initiate crevice corrosion. Examination of the specimen surfaces after corrosion testing showed that in the as-welded specimen, corrosion was present in both the weld dendrites as well as around the secondary phases. However, the specimen solution annealed at 1121 C showed corrosion only at secondary phases and the specimen annealed at 1200 C showed pitting corrosion only in a handful of grains.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
887277
Report Number(s):
UCRL-PROC-216967; TRN: US0604231
Resource Relation:
Conference: Presented at: International High-Level Radioactive Waste Management Conference, Las Vegas, NV, United States, Apr 30 - May 04, 2006
Country of Publication:
United States
Language:
English