Title: 45-day safety screen results and final report for tank 241-C-202, auger samples 95-Aug-026 and 95-Aug-027

Technical Report ·
DOI:https://doi.org/10.2172/88544· OSTI ID:88544

Two auger samples from tank 241-C-202 (C-202) were received at the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. Two samples were submitted for energetics determination by DSC. Within the triplicate analyses of each sample, one of the results for energetics exceeded the notification limit. The sample and duplicate analyses for both augers exceeded the notification limit for TGA. As required by the Tank Characterization Plan, the appropriate notifications were made within 24 hours of official confirmation that the limits were violated.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
88544
Report Number(s):
WHC-SD-WM-DP-132; ON: DE95016329; TRN: 95:017944
Resource Relation:
Other Information: PBD: 19 Jun 1995
Country of Publication:
United States
Language: